Basic Info.
Main Application
Water, Wastewater, Corrosive Liquid/Gas
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Liner Material
Cr, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Electrode
316L Ss, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Output
4-20mA, Pulse, RS485, Hart, Profibus
Transport Package
Carton or Wooden Box
Product Description
Measuring Chemicals Solution Magnetic Flow Meter1. IntroductionMLF electromagnetic flow meter, composed of sensor and converter, works based on Faraday's law of electromagnetic induction law. It is used to measure electrical conductivity of liquid or solid. Generally, the electrical conductivity should be over 5υS/cm(electrical conductivity of tap water, raw water is about 100~500υS/cm),It can also be used to measure various media like acid, alkali, saline solution, paper pulp or pulp and so on. But these media can't contain a lot of magnetic materials and bubbles.MLF electromagnetic flow meter is a kind of instrument which is used for measuring the flow conductivity liquid. The meter is widely used in flow measuring of Metallurgy, Chemical Industry, Paper Industry,Environmental Protection, Oil Industry, Textile Industry, Food Industry and City Administration, Water Works,etc.2. Working PrincipleThe principle of the sensor is based on Faraday's law of electromagnetic induction. It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and produces induced electromagnetic force.Which can be measured by the two electrodes on the meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal) E=KBDVE--Induced electromotive force,V;K--meter constant;B--Magnetic flux density,T;D--Internal diameter of measuring pipe,m;V--Average velocity of pipe section,m/s.1MLF Series Electromagnetic Flow MeterAssume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv, K is meter constant,K=4kB/πD.Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the measuring electrodes inspect the electromotive force, and transmit to the converter, the converter provides excitation current. E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,adjusting can be achieved.3. Quick Details- The MLF electromagnetic flow meter is for explosive proof design.
- It as the function of low conductivity measurement.
- It has 9 languages for option to satisfy different customers' requirements.
- It has the function of self-adjustment and self-checking.
- A variety of outputs are optional:Hart, RS485, Profibus, 4-20mA, Frequency, Pulse.
4. SpecificationMLF Type | Divided Type | Integrated Type | Explosive Proof Integrated Type | Battery Powered Type | Heat Energy Type |
Accuracy | ±0.2% or ±0.5% |
Pipeline Diameter | DN10-DN2000 | DN10-DN600 | DN25-DN2000 |
Flange | GB, ANSI, JIS, BS, Others |
Pressure | DN10-DN600 1.0 1.6 2.5 4.0MPa |
DN700-DN2000 0.6 1.0 1.6MPa |
Liner Material | CR, PTFE, PU, Hard Rubber, PFA, FEP(F46) |
Conductivity | ≥5µs/cm(Please contact us if it is less than 5µs/cm) |
Electrode | 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others |
Protection Class | IP65, IP66, IP67, IP68 |
Medium Temperature | -25~180ºC (Please refer to liner material) | -25~80ºC(Please refer to liner material) | -25~180ºC (Please refer to liner material) |
Ambient Temperature for Accuracy Influence | <±0.1%/10ºC or <±0.25%/10ºC at the ambient temperature of -25~60ºC |
Repetability | ≤±0.1% or ±0.25% |
Analog Output Error | ≤±0.02mA |
Velocity | 0.3~10m/s |
Electrical connection | M20x1.5 Seal Cartridge, GB1/2, NPT1/2 |
Output | 4-20mA, Pulse, RS485, Hart, Profibus |
5. Selection of Liner MaterialLiner Material | Main Performance | Application |
PTFE | 1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion. 2 Low wear resistance. 3 Low negative pressure resistance. | 1. -25~140ºC 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare medium |
CR | Oil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc. | 1. <80ºC 2. Be able to measure sewage and mud |
PU | 1. Very good abrasive resistance, flexibility. 2. Low acid and alkali resistance. | 1. <65ºC 2. Neutral strong abrasion resistance medium |
Hard Rubber | 1 Room temperature resistance, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid,sodium hydroxide, potassium hydroxide 2 Avoid strong oxidants
|
| 1. <80ºC 2. General acid, alkali, salt solution |
PFA | 1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant. 2. High material strength, resistance to aging, better than PTFE, EFP in high temperature 3. Injection molding for higher negative pressure | 1. 40~180ºC 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare mdium |
FEP(F46) | 1. Hydrophobicity and non-viscous 2. Corrosion resistance is inferior to PFA 3. Negative pressure | 1. 40~180ºC 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare mdium |
6. Selection of Electrode MaterialsElectrode Material | Main Performance |
316L | Good nitric acid corrosion resistance, <5% sulfuric acid, acetic acid, alkaline liquid, sulfite under certain pressure, sea water, acetic acid, etc. corrosion at room temperature, can be widely used in petrochemical urea, vinylon, etc. |
Hb | Good resistance to all hydrochloric acid with a concentration lower than the boiling point, and also resistant to corrosion by non-oxidizing acids, alkalis, sulfuric acid, phosphoric acid, hydrofluoric acid, and organic acids. |
Hc | Corrosion resistance to oxidizing acids, such as nitric acid, mixed acids. A mixture of chromic acid and sulfuric acid, oxidizing salts such as Fe3+, Q3+, and some other oxidizing agents, such as a mixture of hypochlorite solution and seawater at higher than normal temperature. |
Ti | It is resistant to corrosion by sea water, various chlorides, hypochlorites, oxidizing acids (including fuming nitric acid), organic acids or alkalis, but not resistant to corrosion by pure reducing acids (such as sulfuric acid and hydrochloric acid). However, if the acid contains oxidants (such as nitric acid, Fe3+, Q3+), the corrosion resistance will be reduced. |
Ta | Good corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid. |
Pt-Ir | Have good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium |
Tungsten Carbide | For pulp and sewage, good resistance to solid particle interference. |
7. ConfigurationMLF Series Electromagnetic Flow Meter Configuration |
Model | MLF |
Sensor Installation | S | Flange Type Sensor |
C | Insertion Type Sensor |
O | Others |
Pipeline Diameter | 10 | 10mm |
15 | 15mm |
20 | 20mm |
...... | |
2000 | 2000mm |
Electrode Installation | F | Standard Fixed Type |
Electrode Material | A | 316L SS |
B | Hb |
C | Ta |
D | Ti |
E | Hc |
F | Tungsten Carbide |
G | Others |
Liner Material | R | Rubber |
P | PTFE |
O | Others |
Pipe Material | B | 304 SS (Standard) |
C | 316 SS |
Flange Type | G | GB (Standard) |
A | ANSI |
J | JIS |
B | BS |
O | Others | |
Flange Material | A | 304 SS |
B | 316 SS |
C | #20 Carbon Steel (Standard) |
Cover Material | D | 304 SS |
E | 316 SS |
F | Carbon Steel+ Epoxy Metallic Paint (Standard) |
Matching Flange | 0 | Without Matching Flange (Standard) |
1 | With Matching Flange |
Ground Ring | 0 | Without Ground Ring (Standard) |
1 | With Ground Ring |
Rated Pressure | 10 | 1.0MPa |
16 | 1.6MPa |
25 | 2.5MPa | |
40 | 4.0MPa |
Working Temperature | E | ≤60ºC |
H | ≤180ºC(Divided Type) |
Type | I | Integrated Type |
D | Divided Type |
Output | P | Pulse |
A | 4-20mA |
G | RS485 |
H | Hart |
Q | Others |
Power Supply | 0 | 220VAC |
1 | 24VDC |
2 | Battery-powered |
Protection Class | 0 | IP65 (Integrated/Divided Type) |
1 | IP67 (Divided Type) |
2 | IP68 (Divided Type) |
Other Features | R | Heat Energy Function |
P | With PT1000 |
B | Without PT1000 |
Explosion Proof | 0 | None |
EX | Explosive Proof |
8. Instrument testing and maintenanceThe electromagnetic flowmeter has a self-diagnostic function. In addition to power supply and hardware circuit failures, the system also alarms other failures in general use. These messages will give corresponding prompts in the lower right corner of the screen.1 Maintenance and repaira) The sensor installation site should meet the requirements of Section 4, please keep the housing tidy;b) The transmitter should be placed in a clean, ventilated and dry place;c) It needs to be inspected every two years. For high-precision users, the instrument needs to be submitted for review.2 Transportation and storagea) The instrument must be packaged before transportation, and be handled with care when loading and unloading.b) The storage place must be dry and ventilated to avoid corrosive gases, and the ambient temperature should not be too low or too high;c) The storage time should not exceed three years.3. Unpacking inspectiona) The package cannot be opened with a heavy hammer, be careful not to damage the instrumentb) Check the contents carefully according to the packing list.
Address:
No. 21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Industrial Equipment & Components, Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.
Our products are widely used in various fields, including electricity, chemical industry, metallurgy, brewing, oil and gas, textile, water conservancy, environmential protection, etc.
We own independent-courtyard modemized manufacturing workshops and an open office building. Melan has accumlated production and management experience in instruments from European and American and domestic famous companies.
We own first-class talent team, and all the products have reached advanced level at home and abroad. We provide our customers with complete and professional test control solutions and high-tech and high-quality products.
Melan is your reliable friend and partner. We are willing to try our best as dedication and perfection as motivation.
High technological and service performance
With numerous wholly-owned subsidiaries and partners, Melan competently and reliably supports its customers worldwide. Our experienced engineers and sales experts are your competent and dependable contacts locally.